Find Volvo Diesel Generator Set, Volvo Deisel Generator , Volvo Engine Diesel Generator on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Home > Products > Volvo Diesel Generator Set > 500kVA Diesel Genset Powered by Volvo Engine (TAD1641GE)

500kVA Diesel Genset Powered by Volvo Engine (TAD1641GE)

Basic Info

Model No.:  KJ-V625

Product Description

Model NO.: KJ-V625 Installation Method: Fixed Cooling Method: Water Cooling Speed: Speed Usage: Common Units Excitation Mode: AC Rotating Exciter Rated Voltage: 400/230V, Various Voltage Available Function Option: ATS, AMS, Synchronization, High Voltage, etc Quality Standard: ISO9001 Export Market: Globally Specification: ISO9001. CE. SONCAP HS Code: 850212000 Type: Basic Diesel Generator Stroke: Four Stroke Output Type: AC Three Phase Conditions of Use: Land Use Landuse Type of Unit: Ordinary Frequency: 50Hz, 60Hz for Option Controller: Smartgen 6110 (Deepsea for Option) Generator Type: Open Type/Silent Type /Container Type/Trailer Type Alternator: Kaijie (Leroy Somer, Stamford for Option) Trademark: Kaijie Origin: Anhui Hefei Product Description-500kva Volvo power diesel generator with CE ISO
1.Power by Volvo Engine
2.With Stamford / Leroy Somer / Marathon Alternator
3. With CHINT / ABB MCCB & Electronic Components
4. Electric Start with Battery
5. Base Integrated Fuel Tank
6. ATS, Deepsea / ComAp / Smartgen Controller
7. Comply with ISO9001/CE 
8. After-sale Services

Control Systems

Standard control panel is the basic configure for normally operation and usage. The advantages of this panel are easy operation, aomprehensive function and reliable protection and so on. There are indicating gauges, lamps, transfer switches and emergency stop button, etc. The control panel wil stop the whole generator set and alarm as well when malfunction appears.

LED Automatic Control Panel is a kind of intelligent controller with LED displaying the operating mode of the controller and the running state of the generator sets. It can configure the control procedure and protection parameter of the generator set, and completely satisfied the automatic controlling requirement of the generator sets for the user or factory.

AMF Automatic Control Panel is the configuration for nobody on duty controlling generator sets. This kind of panel adopts module control system, with large LCD screen to show the menu. The module can receive output signal from ATS and realize automatic start and stop the generator set.

ATS(Fully Automatic) is the standard configure of emergent power system. It detects the voltage and frequency of main power timely. While there is something wrong, such as high voltage, low voltage, phase missing, electricity cutting off, etc., it will signal to start the generator set automatically; 
While main power resumes balanced, it controls the generator set to shut down after cooled.

Engine
*Heavy duty diesel engine
*Four stroke, water cooled
*12V and 24V stater and charge alternator
*Cooling radiator and fan
*Maintenance free battery including ract and cable
*Flexible fuel connection hoses and manual oil sump drain valve
*Exhaust silencer
Alternator
*Brushless, single bearing, flexible disc
*Insulation class: H
*Protection class: IP23
*Self-exciting and Self-regulation
Canopy
*All canopy designed with modular principles
*All metal canopy parts painted by electrostatic polyester power paint
*Soundproof design ensure that the noise level be controlled in small scope
*Convenient to lift and move
*Easy to maintenance and operate
 
Base Frame
*Base frame including position for forklift and crane
*Integral fuel tank
*Daily fuel tank continuously supply for 8-24 hours
*Fuel tank easy to maintain and clean
*Anti-vibration pads are flexed between engine and alternator.
 
Control System
*Control, monitor and protect the Generator Set including:
*High water temperature
*Low oil pressure
*Over and under speed
*Over current
*Under/Over generator voltage
*Start and stop failure
*Low and high battery voltage
*Charge fail
*Emergency stop

Genset Model Standby/Prime Power Standby/Prime Power Rated Fuel cons. 100%              (g/kw.h) Engine Model Type Cyli-nder Bore×Stroke Disp. Dimension Weight
KVA KW mm L L×W×H(mm) kg
KJ-V94 94  85  75  68  213 TAD520GE In line, direct injection,               4-stroke,             water cooled 4L 108×130 4.76 1800×700×1300 1000 
KJ-V109 110  100  88  80  218 TAD531GE 4L 108×130 4.76 2000×700×1500 1200 
KJ-V142 142  130  114  104  214 TAD532GE 4L 108×130 4.76 2300×850×1500 1300 
KJ-V165 165  150  132  120  215 TAD731GE 6L 108×130 7.15 2300×850×1500 1500 
KJ-V206 206  185  165  150  213 TAD732GE 6L 108×130 7.15 2450×900×1500 1600 
KJ-V220 220  200  176  160  216 TAD733GE 6L 108×130 7.15 2500×950×1600 1800 
KJ-V275 275  250  220  200  204 TAD734GE 6L 108×130 7.15 2650×1000×1700 2200 
KJ-V358 358  325  286  260  202 TAD941GE 6L 120×138 9.36 2800×1100×1700 2500 
KJ-V415 412  375  330  300  192 TAD1343GE 6L 131×158 12.78 3000×1100×1750 2800 
KJ-V450 450  410  360  328  194 TAD1344GE 6L 131×158 12.78 3000×1100×1750 2850 
KJ-V500 500  450  400  360  196 TAD1345GE 6L 131×158 12.78 3100×1200×1800 3000 
KJ-V550 550  500  440  400  199 TAD1641GE 6L 144×165 16.12 3100×1200×1800 3200 
KJ-V625 630  570  505  456  201 TAD1642GE 6L 144×165 16.12 3200×1200×1800 3500 
KJ-V700 700  630  560  505  199 TWD1643GE 6L 144×165 16.12 3200×1300×1850 3800 
500kVA Diesel Genset Powered by Volvo Engine (TAD1641GE)
500kVA Diesel Genset Powered by Volvo Engine (TAD1641GE)

Contact us if you need more details on Diesel Generatos. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Power Generator、Electric Generator. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Volvo Diesel Generator Set